A Global Exchange for High-Quality Equipment
Call us + 632.8671.9888
or get a FREE QUOTE
CNC Machines
Eastar Precision Slotting Machine
* Special design worm and worm gear with linkage transmission mechanism, well construction and highly power output.
* The ram-sliding surface are hardened and precision ground.
* Built in lubricating system for smoothly running and prolong the life of head.
Eastar Shearing Machine SSA-Series
Electrical/Mechanical Power Shear
Thickness:4.5~6.5mm
Length:1250~3050mm
Nabertherm Air Circulation Chamber Furnace
Application: Advanced Materials
Chamber furnaces with air circulation are characterized particularly by their very good temperature uniformity. As a result, they are well suited for processes such as calcination and drying e.g. ceramic materials. The design as a debinding furnace for safe debinding in air or in an inert atmosphere is possible. When used for debinding in air the exhaust gases are diluted by fresh air to reliably prevent an inflammatory atmosphere in the furnace chamber. For debinding processes that have to take place under inert gas, the IDB passive safety concept with a residual oxygen content of max. 3 % is recommended.

Tmax 450  °C, 650  °C, or 850  °C
Stainless steel air-baffles in the furnace for optimum air circulation
Swing door hinged on the right side
Base frame included in the delivery, N 15/65 HA designed as table-top model
Horizontal air circulation
Temperature uniformity up to +/- 5 °C according to DIN 17052-1 (model N 15/65 HA up to +/- 7 °C)
Optimum air distribution enabled by high flow speeds
One removable tray and rails for two additional trays included in the scope of delivery (N 15/65 HA without removable tray)
Defined application within the constraints of the operating instructions
NTLog Basic for Nabertherm Controller: Recording of process data with USB-flash drive (NA 30/45 - N 675/85 HA)
Additional equipment (not for model N 15/65HA)
Optimization of the temperature uniformity up to +/- 3 °C according to DIN 17052-1
Fan cooling to accelerate the cooling process
Motor driven exhaust air flaps
Manual lift door (up to model N(A) 250/.. (HA))
Pneumatic lift door
Adjustable air circulation for sensitive components
Additional removable trays
Roller conveyor in furnace chamber for heavy charges
Designed for Tmax 950  °C
Debinding packages with safety concept starting from 120 liters volume, see page 6 - 8
Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control
Nabertherm Chamber Ovens, Ovens for Laminated Safety Glass (LSG) Electrically Heated or Gas-Fired
Application: Glass
The chamber ovens of the KTR range can be used for complex drying processes and heat treatment of charges to an application temperature of 260 °C. The high-performance air circulation enables optimum temperature uniformity throughout the work space. A wide range of accessories allow the chamber ovens to be modified to meet specific process requirements. The design for the heat treatment of flammable materials in conformance with EN 1539 (NFPA 86) is available for all sizes.

The chamber ovens can also be used for production of laminated safety glass (LSG). During this process two panes are bonded using a laminating foil and entered into the oven inside a vacuum bag. From outside the furnace a vacuum is generated via hose connection in order to avoid air inclusions between the panes during the heat treatment.

Tmax 260  °C
Electrically heated (via a heating register with integrated chrome steel heating elements) or gas-fired (direct or indirect gas-fired including injection of the hot air into the intake duct)
Temperature uniformity up to +/- 3  °C according to DIN 17052-1 (for design wihout track cutouts)
High-quality mineral wool insulation provides for outer temperatures of < 25  °C above room temperature
High air exchange for fast drying processes
Double-wing door for furnaces KTR 3100 and larger
Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the oven and load
Incl. floor insulation
Defined application within the constraints of the operating instructions
NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Additional equipment
Track cutouts for level drive-in of charging cart
Connection ports for vacuum bags inside the oven for laminated safety glass (LSG). The vacuum pump is connected on the outside of the furnace.
Base frame to charge the oven via a charging forklift
Additional Door in the back for charging from both sides or to use the oven as lock between two rooms
Fan system for faster cooling with manual or motor-driven control of the exhaust air flaps
Programmed opening and closing of exhaust air flaps
Air circulation with speed control, recommendable for processes with light or sensitive charge
Observation window and furnace chamber lighting
Safety technology according to EN 1539 (NFPA 86) (models KTR .. LS) for charges containing solvents
Charging cart with or without rack system
Design for clean room heat treatment processes
Rotating systems for tempering processes
Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control
Accessories
Adjustable plate shutters to adapt the air guide to the charge and improve temperature uniformity
Guide-in tracks and shelves
Shelves with 2/3 extraction with evenly distributed load on the whole shelve surface
Platform cart in combination with drive-in tracks
Charging cart with rack system in combination with drive-in tracks
Sealing shoes for ovens with drive-in tracks to improve temperature uniformity in the work space
All KTR-models are also available with Tmax 300 °C.
Nabertherm LHT 01/17 D
Application: Dental
These high-temperature furnaces are perfectly suited for sintering of translucent zirconia units. The special molybdenum discilicide heating elements offer best possible protection against chemical interaction between charge and heating elements. The zirconia units are positioned in ceramic saggars. Up to three saggars can be stacked into the high-temperature furnace.

Tmax 1650  °C
Furnace chamber with a volume of 1 or 2 liters
Special heating elements made of molybdenum disilicide offer best possible protection against chemical interaction between charge and heating elements
Furnace chamber insulation made of non-carcinogenic fiber materials
Housing made of sheets of textured stainless steel
Dual shell housing with additional fan cooling for low surface temperature
Compact design with lift door, opening upwards
Adjustable air inlet
Exhaust air opening in the roof
Type S thermocouple
Precise temperature control, also in the lower temperature range for drying
Controller P480 (LHT 01/17 D) or P470 (LHT 03/17 D)
Switchgear with steady control of the heating elements
Delivery incl. starter set to charge the zirconia works
Defined application within the constraints of the operating instructions
NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Additional equipment
Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
Saggar for charging of up to three layers
Protective gas connection for non-flammable protective or reaction gases for LHT 03/17 D
Manual or automatic gas supply system
Process control and documentation via VCD software package for monitoring, documentation and control

Application:  DENTAL
Nabertherm Muffle Furnaces with Flap Door or Lift Door
Application: Laboratory
The muffle furnaces L 1/12 - LT 40/12 are the right choice for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.

Tmax 1100 °C or 1200 °C
Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12)
Ceramic heating plates with integral heating element which is safeguarded against fumes and splashing, and easy to replace
Insulation made of non-classified fiber material
Housing made of sheets of textured stainless steel
Dual shell housing for low external temperatures and high stability
Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
Adjustable air inlet integrated in door (see illustration)
Exhaust air outlet in rear wall of furnace
Solid state relays provide for low-noise operation
Defined application within the constraints of the operating instructions
NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Additional equipment
Chimney, chimney with fan or catalytic converter (not for L 1)
Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
Protective gas connection to purge with non-flammable protective or reaction gases (not available in combination with chimney, chimney with fan or catalytic converter)
Manual or automatic gas supply system
Process control and documentation via VCD software package for monitoring, documentation and control.
Nabertherm NB 4330/S - Chamber furnace
Application: Thermal Process Technology
Certain heat treatment processes require a gas-fired chamber furnace. Short heating times due to the high power are a convincing argument. The chamber furnaces with powerful atmospheric gas burners cover a wide variety of these processes. In the basic version the burners are manually ignited once at the start of the process. The automatic control system then takes over control of the temperature curve. At program end, the burners are automatically switched off. Depending on the process, the furnaces can be equipped with automatically controlled fan burners and safety technology for debinding. Depending on the model, these furnaces can be upgraded with fully automatic fan burners and additional accessories.

Tmax 1300  °C
Powerful, atmospheric burners for operation with liquified gas or natural gas
Depending on the application, special positioning of the gas burners with flame guidance provides for optimal temperature uniformity
Fully automatic temperature control
Gas fittings with flame control and safety valve in accordance with DVGW (German Technical and Scientific Association for Gas and Water)
Multi-layer, reduction-proof insulation with light-weight refractory bricks and special back-up insulation result in low gas consumption
Self-supporting and rugged ceiling, bricks laid in arched construction or as fiber insulation
Exhaust hood
Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load
Defined application within the constraints of the operating instructions
Additional equipment
Fan burner with fully automatic control
Indirect gas firing with radiation tubes for flame protection of the charge
Exhaust air and exhaust gas piping
Thermal or catalytic exhaust cleaning systems
Recuperator technology for heat recovery
Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control
Nabertherm NW 150 - NW 1000/H
Chamber Kilns with Drawer Bottom or as a Bogie
The chamber kiln of NW model series combines the attractive quality advantages of the proven models N 150 - N 1000/H with an outstanding product characteristic which substantially simplifies charging.

With a drawer mechanism (NW 150 - NW 300/H) the kiln table can be easily pulled out of the chamber kiln. The larger models NW 440 - NW 1000/H are designed as shuttle kiln with completely free traversing bogie. Free access in front of the chamber kiln allows for a simplified and clear charging the kiln.

Dual shell housing, galvanized steel sheets
Front made of textured stainless steel
Environment-friendly, long-life powder-coating of housing
Rugged, self-supporting, vaulted arch construction
Controller mounted on kiln door and removable for comfortable operation
Multi-layer insulation with light-weight refractory bricks and high-quality, energy-saving backing insulation
Lightweight refractory bricks inside kiln chamber for clean firing results
Dual shell door with long-live sealing
Kiln table can be easily pulled-out (NW 150 - NW 300/H)
From chamber kiln NW 440 bogie on four castors (two with brakes) which can be pulled out completely. Accession assistance and removable drawbar for bogie
Door sealing grinded by hand (brick on brick); NW 150 - NW 300/H
Door is adjustable
Door safety switch shuts down power to the elements when the door is opened
Heating from five sides with special arrangement of heating elements for optimum temperature uniformity
Heating elements of support tubes provide for free radiation of the heat
Solid state relays provide for low-noise operation
Rapid switching cycles result in precise temperature control
Type S thermocouple
Air inlet flap with integrated residual drying function closes the air inlet at a temperature which can be set in the controller for NW 150 - NW 300/H
Exhaust air outlet in the ceiling, motor driven exhaust air flap for chamber kilns NW 440 - NW 1000/H
Delivery incl. pipe connection for connecting an air outlet with 80 mm diameter for NW 150 - NW 300/H
SiC-floor plate protects floor elements and provides a level setting surface
Fixed base
Comfortable charging height with base of 800 mm (chamber kilns NW 440 - NW 1000/H = 500 mm)
Defined application within the constraints of the operating instructions
NTLog for Nabertherm Controller: Recording of process data with USB-flash drive
Nabertherm Tilting Furnaces KB Gas-Fired, for Melting and Holding
Application:  Foundry
The gas-fired or oil-heated tilting furnaces in the KB product lines provide for high melting output, making them ideal for melting operations. The use of high-quality insulation materials results in very low energy consumption. The two-stage burner can be configured for either gas or oil operation. Designed with an exhaust vent over the crucible edge, these models achieve very high melting rates and optimum energy efficiency.

KB../12 with Tmax of 1200 °C for aluminum and zinc alloys
KB../14 with Tmax of 1400 °C, suitable for copper alloys with a maximum melting bath temperature of 1300 °C (appropriate in some cases for aluminum)
Fuel heating with gas or oil
Two-stage output control: High load for melting operation, low load for holding operation with automatic switching between both modes
Modern burner system with optimized flame guide: High efficiency provided by over-pressure operation to keep out entrained air
Gas system consisting of pressure regulator, gas filter, manometer and solenoid valves
Safe flame monitoring
Burner technology with easy-to-service design, e.g. flame head can be removed from the rear when the burner is swung out
Burner technology compliant with DIN 746, Part 2
Designed for natural gas or liquid natural gas with 8.8 kWh/m3 - 25.9 kWh/m3
Required gas input pressure: 50 mbar
Operation with other fuels and/or with another gas input pressure possible
High melting output powered by high-performance burners and high-quality insulation
Crucible made of isostatically pressed clay-graphite
Electro-hydraulic tilting system with flame resistant HFC hydraulic fluid
Safe, uniform and precise pouring enabled by the optimum pivot point of the furnace and the manual operation of the slider valve
Multi-layered insulation with lightweight refractory bricks provide the furnace chamber lining, 1400  °C models come with an additional wear-and-tear layer made of copper-resistant refractory concrete
Emergency outlet for safe discharge of the melt in case of a crucible break
Exhaust gas discharge over the crucible edge, resulting in approx. 20 % more melting output compared to side exhaust discharge, design without swing lid
Over-temperature limiter for the furnace chamber with automatic reset to protect against over-temperature. The limit controller switches off the heating when the pre-set limit temperature has been reached and does not switch it on again until the temperature falls below the setting again.
Furnace chamber control with temperature measurement behind the crucible, recommended when using as pre-melt furnace
Side-wall exhaust gas vent for KB…/12 models, see additional equipment
Additional equipment
Side exhaust gas discharge for melt and holding operation
Low burn-off provides for high quality melt
Low hydrogen absorption by the melt
Low heat exposure for the operator in the area above the crucible
Swing lid which, when closed during holding operation, saves up to 50 % energy
Approx. 20 % lower melting output than for exhaust gas venting over the crucible edge
Insulated connecting piece (exhaust flue) for side-wall exhaust gas vent to a connected customer suction system
Exhaust gas collection hood for furnaces featuring exhaust gas venting over the crucible edge
Work platform or platform for easier charging
Crucible breakage monitoring with optical and acoustic signal (only for models KB ../12)
SMS-message to one or more mobile phones in case of crucible breakage. One or more furnaces can be connected to the messaging device in parallel
Bath control system
Furnace control via the bath temperature
Thermocouples in the furnace chamber and the melt
Improved melt quality ensured by a reduction in temperature overshoots
Integrated safety controller system that, in case of bath thermocouple breakage, continues to operate the furnace at a reduced output to prevent the melt from solidifying
× oeme iso certification